Government & Politics

INSTALLATION AND STARTUP GUIDE

Description
INSTALLATION AND STARTUP GUIDE REV PL-TRA-STARTUP-EN Rue Charles, Suite 100, Mirabel, QC, J7J 1X9 Table of Contents ProLon Installation
Published
of 12
9
Published
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Transcript
INSTALLATION AND STARTUP GUIDE REV PL-TRA-STARTUP-EN Rue Charles, Suite 100, Mirabel, QC, J7J 1X9 Table of Contents ProLon Installation and Start Up Guide... 3 Part 1 - Project Preparation & Cabling... 3 Part 2 - Installing the Components... 4 Part 3 - Electrical Installation / Connections... 5 Part 4 - Start Up... 8 Part 5 - ProLon Focus (Computer Access and Control)... 9 REV / PL-TRA-STARTUP-EN 2 ProLon Installation and Start Up Guide 1 Communication room sensors 4 wire cable (#22/4 shielded cable recommended) 2 Supply/Outputs #18/2 or #18/3 wire, LVT standard 3 Network #24/2 wire, twisted and shielded, low capacitance ( LOW-CAP ) grounded at control cabinet 4 Unit sensors #18/2 or # 18/3 wire, twisted and shielded grounded at control cabinet 5 Wire to unit #18/8 (or #18/10) wire, LVT standard System layout and cabling System Layout and Cabling Part 1 - Project Preparation & Cabling 1. Using a floor plan, determine the system s zone controller locations as well as the unit controller s (control panel) location. Mark them on your plans for later access. 2. The unit and zone controllers must be addressed. Their relative location on the network bus is not important. 3. As a result, determine the shortest path for the network cables as well as the supply cables which connect the controllers together. The communication loop must be an open daisy chain. 4. Once the network path has been determined, identify the two controllers that will be at each extremity of the network. Mark them on your plans. Wiring the Zones in a Network REV / PL-TRA-STARTUP-EN 3 Part 2 - Installing the Components VAV Zone Controller Verify / validate the rotation direction of each zone damper. Close the damper and rotate the actuator clamp to the closed position using the clutch button. Install the zone controller on the damper and set in place with screws and bracket. While pressing the actuator s clutch button, turn the clamp manually, the damper should turn freely (slight off axis movement). Adjust mechanical stoppers to prevent overtravel. Full rotation of actuator should match that of damper. Get the identification address of each zone and write it down inside the cover (or the back plate) of its zone thermostat (very convenient for service calls). Sensors and Accessories 1. Room sensor: Install 60 from the floor. Avoid sunny or outdoor walls, diffusers and return grills. (Especially with bypass boxes.) Beware of electrical boxes (light dimmers)! (PL-T200 / PL-T500 / PL-T100) 1 2. Outside air temperature sensor: Install under air inlet hood or on the unit s north side IN THE SHADE! (PL-OAS) 3. Supply air temperature sensor: Install after the bypass damper junction. Return air temperature sensor: Install before the bypass damper junction (no turbulence). (PL-DS) Static pressure sensor: To be installed 2/3 of the main ventilation duct s length. (PL-MLP) 6 5. Proof of fan (flow switch): Install near the supply air temperature sensor (no turbulence). Plug the high pressure (+) Pitot tube in the air duct. Remove the low pressure cap and leave free. (AFS) 4 P 7 6. CO2 Sensor: Install in the return duct before the bypass junction. (CO2) 5 7. Bypass damper actuator: Mark the damper position on the shaft and validate its opening direction. 4 REV / PL-TRA-STARTUP-EN 4 Part 3 - Electrical Installation / Connections VAV Zone Controller Inputs Wall Sensor (PL-T200/T500/T1000) : 4 wire cable (#22/4 shielded cable recommended) connected to terminals #9 to #12. Changeover Sensor (if required): directly to terminals #13 & #14. Supply 5VA per zone / max 100VA per circuit. Link the #1 & #2 terminals in a daisy chain. Respect the live / common polarity on all controllers. Ground the common (at central transformer). Ground all controllers commons. (if using multiple transformers). Analog Output (0-10VDC) : connect to terminals #7(-) and #8(+). Respect the polarities. Input/Outpout wiring for a VC-2000 Digital Output (24VAC or dry contact): For dry contact, connect to terminals #5 and #6 (no jumper between #4 and #5). For 24VAC output, connect to terminals #3 and #6 (jumper installed between terminals #4 and #5). REV / PL-TRA-STARTUP-EN 5 Network Cabling Check for continuous daisy-chain to all zone controllers. Do not link in a star pattern. Check the A / B network polarity on all zones and unit controller; must all be identical. Join all shields at each controller s junction and connect one end only to the ground lug in the central panel only (unit controller). Check / activate terminating resistor jumpers ( TERM ) on each of the controls located at both ends of the communication network. The network cable must be shielded and twisted, 2 conductors AWG #24, low capacitance only. FASTEN YOUR WIRES TOGETHER AND SECURE THEM TO THE VAV BOX! (TIE-WRAPS, TAPE, ETC). * Enable terminating resistor jumpers (TERM) at both ends of the daisy chain (Unit controller and/or zone controllers). The neutral of the 24VAC supply of the zones must be connected to ground. 6 REV / PL-TRA-STARTUP-EN 6 Unit Controller Check that all (input and output) connections match that of the supplied wiring diagram. Check that all shielded cables have their shield grounded at the central panel s ground lug. Check that the multi-conductor control cable to the unit is connected and 24VAC is available. The control panel s 24VAC power is fed by the RTU. Never connect temperature or other sensors using spare conductors of AC carrying control cable, as this might cause magnetic interference and lead to erratic data reading. Sensors must only use dedicated shielded wiring. M2000 wiring details M2000 Wiring Details REV / PL-TRA-STARTUP-EN 7 Part 4 - Start Up Powering up the zones Check if all terminating resistor jumpers are in place (both ends of the communication loop). Power up the zones supply transformer(s). Make sure that each controller displays it s flashing heartbeat light. If zone controllers are supplied with digital display sensors, (PL-T500/T1000), make sure the sensor display lights up and shows ambient temperature. Make sure all zone dampers open in the proper direction (yellow status light). If not, invert rotation (procedure described in the V.2.0 troubleshooting guide). Powering up the Unit Controller The air handling unit (or RTU) must be on, as it supplies 24VAC power to the unit controller. Power up the controller by closing fused switch (located in the control cabinet). Check that the controller lights up both power indicators (red) 24VAC and 5VDC. Check that the controller displays it s blinking heartbeat (written: hbeat). Approximately ten seconds after powering up, check the network communication status lights NETREC and NETSND on the controller. They should briefly blink together, every three seconds or so, to confirm communication is established with the zones. Inspect all zone controllers as well, making sure the same status lights (NETSND in red and NETREC in green) also blink at the same rate as the unit controller. About 15 seconds following power up, the unit controller should start the ventilation (output DO1 activated). Approximately 5 minutes following power up, the heat or the air conditioning of the unit can come on (initial power up off-delay protection). Quick verification (without the Prolon Focus software and computer) Temporarily disconnect the supply air sensor from the unit controller (do not forget to reconnect!) Option 1 - Cooling To verify cooling, each zone ambient temperature must be equal or above the zone s cooling low set point limit (default: 69ºF / 20.5ºC). Set all the thermostats to call for cooling. The Unit controller will activate its cooling output(s) if all limits, protections and delays have been acknowledged. Check that all zone dampers open for cooling as requested. Reconnect the supply air sensor to the unit controller. Option 2 - Heating To verify heating, each zone ambient temperature must be equal or under the zone s heating high set point limit (77 ºF / 25ºC by default). Set all the thermostats to call for heat. Check for zone terminal heating operation (if applicable). The Unit controller will activate its heating output(s) if all limits, protections and delays have been acknowledged. Check that all zone dampers open for heating as requested. Reconnect the supply air sensor to the unit controller. 8 REV / PL-TRA-STARTUP-EN 8 Part 5 - ProLon Focus (Computer Access and Control) Computer and software In order to avoid problems and delays, make sure to follow these guidelines. Use a laptop computer (with Windows 7 or later software) as well as the most recent version of Prolon Focus. Visit the website to download the latest version. If you are using the Prolon RS485 communication interface for the first time, you must install the driver software that comes with it. Once installed, you must validate the communication port (COM) number your computer assigned to that interface. To find out, go to the Control Panel Settings on your computer, then Systems, then on Hardware and finally click on Device Manager. (Start / Control Panel / Hardware / Device Manager). Click on Ports COM & LPT. The COM port identified as USB Serial Port COMx or RS485 Isolated Port COMx will be the one to use. Opening a session on Prolon Focus Connect the communication interface to the computer (USB cable or serial depending on the model). Connect the network cable (CAT5e / RJ45 male plug) from the interface output to the communication port of the unit controller in the panel (input RJ45 female jack). Open the Focus software by double-clicking on the Prolon icon located on your computer s desktop. Click on Create a new project. Click on Serial Connection. Select amongst the list the communication port number you previously retrieved. A message will appear in the bottom left corner of the screen to confirm Port COM (x) opened. Setting up a new system From the left hand list, double click the desired unit controller icon (eg: Rooftop for a C1000 RTU or M2000 RTU air conditioning controller). Enter the identification address (as on the controller, also determined by the position of the addressing dip-switches). A bright colored icon (green, red or blue) will appear at the top of the screen, symbolizing the unit. Move the mouse s cursor and point the icon, right-click on the mouse to browse the command menu. Click on Get List, the unit controller will scan its network and update the list of zones and these zone icons will begin to appear on the screen. Validate the list of zones, checking all addresses and making sure they have all shown up, according to the project s shop drawings. If some icons are missing, ensure that the controls are supplied in 24VAC. Check the connection to the power supply and to the network (those connections are polarized) and also check on the controller card the status of the following blinking LED s: hbeat, netrec and netsnd. Confirm that all the zones appear in one of the following three colors according to their particular request: green=satisfied, red=heating, blue=cooling. Should an icon appear in grey, communication is lost to that zone. REV / PL-TRA-STARTUP-EN 9 Absolute override authorization Double-click the unit controller and select the Congif menu on the top left corner. Then select Edit display menu. At the bottom of this page check the Enable Absolute Overrides and click OK to confirm your acceptance. Then click Apply. Adjusting the bypass damper Click on the Home button in the upper right to return to the unit controller s home page, click on Network then Other at the bottom of the list. Check the Slave Damper Override, enter 100% and click Apply. Wait for all the zone dampers to display 100% open on the screen. If this has not been checked before, physically confirm that the dampers are open. If necessary, inverse the zone(s) damper s opening direction (see instructions below). Return to the home page and make sure the bypass damper is fully closed (0%). Validate physically. Read the static pressure value on the home screen and then adjust the set point by increasing it by 20% of the reading. To do so, click on Config then Pressure to access the pressure management menu for the bypass damper. Adjust the set point according to your calculations and adjust the differential to 20% of the set point value. Eg: pressure read: 0.20, adjust set point to (pressure read + 20%) = 0.24, 0.05 = differential. Return to the Slave Damper Overrride and enter 25%, click Apply. Check the bypass damper opening on the home page as well as physically according to the increase in pressure. Inverse the opening direction of the bypass damper if need be. Return to the home page, click Network and then Other.Remove the Slave Damper Override. Press Apply. Cooling and heating operations From the home page of the unit controller, point and right-click each item to be checked in order to activate the override mode. You can check the economizer s damper(s) (if applicable), the cooling stage(s), the heating stage(s) and/or the modulating heating output from the unit. Physically check the proper functioning of each of these elements. Return to the Edit Display menu, and remove the absolute overrides and click Apply. Inverting a zone damper s opening direction To invert the damper s opening direction, double-click the zone controller icon to open its menu, then double-click directly on the zone damper shown on the screen. You then access the page: Damper Configuration. At the bottom of this page, Damper Setup, choose the correct opening direction (clockwise or counterclockwise) and then click Apply. Physically confirm. Date and time From the unit controller s home screen, check that the date and time are correct. To modify them, click on Edit and then click Copy to copy the computer s date and time, or manually type the change then click OK. 10 REV / PL-TRA-STARTUP-EN 10 Schedule Also from the unit s home screen, click Network and then Schedule to access the schedule configuration page. Double-click the ON line in the Monday column. While the cursor flashes in the middle of this period, type the start Occupied pediod. Eg: 6 to start the occupied period at 6:00am or 630 for 6:30am. Double-click the OFF line in the Monday column. While the cursor flashes in the middle of this period, enter the time to end the Occupied period. Eg 16 for 16:00 (4:00pm) or 1745 for 17:45 (5:45pm). To copy a schedule, click the day to copy on the Copy from dropdown list and then check the other days which will have the same schedule in the Paste to list. Click Paste and then click Apply. Rename zones and units From the basic system screen, right-click a zone or unit controller s icon, select Rename and type the zone or unit s name and click OK. Save Click on File in the upper left corner. Choose Save or Save As to save the configuration file (.prl file). Exit Click on File in the upper left corner, choose Exit or click on the X in the upper right corner to close Focus. Advanced Configurations Focus provides many other settings to optimize the operation of your systems. However this guide is a quick start guide, we invite you to consult the complete documentation online REV / PL-TRA-STARTUP-EN 11 REV PK-TRA-STARTUP-EN Copyright 2017 ProLon. All rights reserved. No part of this document may be photocopied or reproduced by any means, or translated to another language without prior written consent of ProLon. All specifications are nominal and may change as design improvements are introduced. ProLon shall not be liable for damages resulting from misapplication or misuse of its products. All trademarks are the property of their respective owners. REV / PL-TRA-STARTUP-EN 12
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x