ABB. M2M Basic. Instructions for assembly and use. Power meter. M2M Basic. M2M Basic Modbus 2CSG445010D0201 2CNM203002R2001 2CNM203001R PDF

Description
2CNM203002R2001 Modbus 2CNM203001R2001 2CSG445010D0201 Instructions for assembly and use Power meter Translation of Original Instructions ABB CONTTS ABB 1 GERAL INFORMATION 1.1 Reference regulations and
Published
of 46
1293
Published
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Transcript
2CNM203002R2001 Modbus 2CNM203001R2001 2CSG445010D0201 Instructions for assembly and use Power meter Translation of Original Instructions ABB CONTTS ABB 1 GERAL INFORMATION 1.1 Reference regulations and conformity Use and storage of the manual Storing Copyright General safety warnings PACKAGING CONTTS 2.1 Description of the contents TECHNICAL CHARACTERISTICS 3.1 Description of the device Measuring functions Overall dimensions Technical data INSTALLATION 4.1 Assembly Disassembly Wiring diagrams Configurations for first use OPERATING 5.1 Front panel Configuration mode Accessing the configuration menu Data entry Enabling the configuration Primary of the CT Secondary of the CT Primary of the VT Secondary of the VT Type of connection Energy resolution Communication baud rate Communication byte format Communication Address Language LED energy pulse Display control Display timer Password modification Critical configuration counter Firmware revision Configuration menu exit...31 Rev. 1.0 Power meter 3 ABB CONTTS 5.3 Data reading mode Accessing the data reading menu Visualization of measured parameters M2M SW software Installing M2M SW software How to update firmware Connecting Modbus to M2M SW Remote data reading and device configuration TROUBLESHOOTING 6.1 Frequently asked questions Power meter Rev. 1.0 Chapter 1 GERAL INFORMATION 1 GERAL INFORMATION ABB 1.1 Reference regulations and conformity 2014/35/EU (Low Voltage Directive) Electrical safety Electromagnetic compatibility IEC IEC /30/EU (EMC Directive) IEC Use of hazardous substances 2011/65/EU (RoHS Directive) Measuring instruments IEC Degree of protection IEC Standardised dimensions for the panel IEC Rev. 1.0 Power meter 5 ABB Chapter 1 GERAL INFORMATION 1.2 Use and storage of the manual Carefully read this manual and adhere to the indications described prior to using the device. This manual contains all of the safety information, the technical aspects and the operating necessary to ensure the correct use of the device and maintain it in safe conditions. ABB cannot be held liable for any damage or personal injury arising from incorrect or improper use of its equipment. This document is subject to changes without prior notice. This manual refers to the instrument firmware version V.1.07 or later Storing The manual must be stored close to the device; safe from liquids and anything else which may compromise its leggibility. The manual and the declaration of conformity are both an integral part of the device until it is dismantled. If the manual is lost or illegible please request a copy from the manufacturer Copyright The copyright of this manual is the property of ABB S.p.A. This manual contains texts, designs and illustrations of a technical nature which must not be disclosed or transmitted to third parties, even partially, without the written authorization of ABB S.p.A. 6 Power meter Rev. 1.0 Chapter 1 GERAL INFORMATION 1.3 General safety warnings ABB Non-adherence to the following points can lead to serious injury or death. Use the suitable personal protection devices and adhere to the current regulations governing electrical safety. This device must be installed exclusively by qualified personnel who have read all of the information relative to the installation. Check that the voltage supply and measurement are compatible with the range permitted by the device. Ensure that all current and voltage supplies are disconnected prior to carrying out any controls, visual inspections and tests on the device. Always assume that all circuits are under voltage until they are completely disconnected, subjected to tests and labelled. Disconnect all of the power supply prior to working on the device. Always use a suitable voltage detection device to check that the supply is interrupted. Pay attention to any dangers and carefully check the work area ensuring that no instruments or foreign objects have been left inside the compartment in which the device is housed. The correct use of this device depends on a correct manipulation, installation and use. Failure to adhere to the basic installation information can lead to injuries as well as damage to the electric instruments or to any other product. NEVER connect an external fuse in by-pass. Disconnect all of the input and output wires before carrying out a dielectric rigidity test or an insulation test on an instrument in which the device is installed. The tests carried out at a high voltage can damage the device's electronic components. Rev. 1.0 Power meter 7 ABB 2 PACKAGING CONTTS Chapter 2 PACKAGING CONTTS 2.1 Description of the contents The packaging includes: 1) power meter 2) installation manual 3) calibration certificate 4) assembly accessories Prior to using the product read the documentation attached and strictly adhere to the indications provided. 8 Power meter Rev. 1.0 Chapter 3 TECHNICAL CHARACTERISTICS 3 TECHNICAL CHARACTERISTICS ABB 3.1 Description of the device is a digital power meter that allows the effective measurement of more than 40 electrical parameters on 3-phase and monophase networks. The power meter is suitable for panel door mounting. It is equipped with a red LED HMI easy to view and four buttons keyboard for the navigation and configuration of the meter. supports serial communications through the RS-485 Modbus RTU communication interface which allows to remotely configure and monitor the device through the software M2M SW. 3.2 Measuring functions is able to measure and process the quantities shown below. 1) Voltages(phase neutral and concatenated) 2) Currents (phase and neutral) 3) Average current values on 15 minutes 4) Cosphi phases and the 3-phase system 5) Active and reactive for the 3-phase system on 4 quadrants (monitoring of energy absorbed and generated by the system) 6) Apparent energy for the 3-phase system 7) Active, reactive and apparent power phases and the 3-phase system 8) Average active, reactive and apparent power values on 15 minutes for the 3-phase systems 9) Voltage and current THD expressed in percent values 10) Current and voltages unbalances expressed in percent values Rev. 1.0 Power meter 9 ABB 3.3 Overall dimensions A Chapter 3 TECHNICAL CHARACTERISTICS D E B C F A B C 96 mm D 96 mm E 90 mm F 102,3 mm 94,3 mm 8 mm X IEC X ,8 mm Y ,8 mm Y 10 Power meter Rev. 1.0 Chapter 3 TECHNICAL CHARACTERISTICS 3.4 Technical data ABB Auxiliary power supply Voltage range [V] V ac / V dc Protection fuse T 0,5 A Frequency range [Hz] Power consumption Measurement type [VA] 3 max Sampling TRMS Accuracy class Voltage ±0,5% reading value According IEC Current ±0,5% reading value According IEC Frequency ±0,2% reading value According IEC Power factor ±1% reading value According IEC Active power ±1% reading value According IEC Reactive power ±1% reading value According IEC Active energy ±1% reading value According IEC Voltage Current Frequency Power factor Cosphi Measurement range VL-N, VL-L [V] Auto range from 20 ma to 6 A TRMS [A] Auto range from 45 to 65 Hz [Hz] Visualisation with 2 decimals Visualisation with 3 decimals Visualisation with 3 decimals Rev. 1.0 Power meter 11 ABB Chapter 3 TECHNICAL CHARACTERISTICS Installation Low voltage Distribution networks Singlephase insertion 3-phase with neutral 3-phase without neutral Ammetric inputs [A] Always use external CT Primary from 1 to A a.c. approx. Secondary 5 A and 1 A a.c. approx. Voltmetric inputs [V] Direct insertion up to 300 a.c. approx. Indirect insertion with VT: Primary from 40 to 800k V a.c. approx. Secondary from 40 to 300 V a.c. Protection fuse [A] 0,1 Data referesh rate Harmonic distortion 1 time/second [Hz] Measurement bandwidth up to 2000 Hz Energy measurement 3-phase maximum value counted 10 GWh / Varh / VAh Ammetric inputs Volumetric inputs RS485 Serial port Terminal characteristics Section 3.3 mm 2 - Step 9.5 mm Section 2.5 mm 2 - Step 7.62 mm Section 1.5 mm 2 - Step 3.81 mm 12 Power meter Rev. 1.0 Chapter 3 TECHNICAL CHARACTERISTICS ABB Overall dimensions 96 mm x 96 mm x mm (Depth inside switchboard: 94.3 mm) Weight [Kg] max Standard normatives Degree of protection IEC Accuracy class IEC Electrical safety IEC IEC Display Display type Display dimensions User interface Navigation through the measurement data LED [mm] 75x60 Communication interface RS485 Protocol Modbus RTU Electric standard RS485 with optical isolation Baud rate 4.8, 9.6, 19.2, 38.4 kbps Parity number Odd, Even, None Stop bit 1, 2 Address Connector 3 pole terminal Climatic conditions Storing [ C] from -40 to +85 Operation [ C] from -25 to +70 Relative humidity Max 75% (without condensation) at 40 C Frontal At terminals Degree of protection IP50 IP20 Rev. 1.0 Power meter 13 ABB 4 INSTALLATION 4.1 Assembly IEC Chapter 4 INSTALLATION A x 2 B x A A B B 14 Power meter Rev. 1.0 Chapter 4 INSTALLATION ABB 4.2 Disassembly B 1 B 2 1 A A 2 3 Rev. 1.0 Power meter 15 ABB Chapter 4 INSTALLATION 4.3 Wiring diagrams The operations to carry out for the correct connection of the device, based on the type of electric line available, are described in this section. The installation and the cabling of the device must be carried out by qualified personnel. Danger of electrocution, burning and electric arc. Use the personal protection devices suitable to adhere to the current regulations governing electrical safety. Prior to carrying out any connections check the sectioning of the electric supply with the voltage detection device. 16 Power meter Rev. 1.0 Chapter 4 INSTALLATION ABB MODBUS Rev. 1.0 Power meter 17 ABB Chapter 4 INSTALLATION 1 3-phase + neutral with 3 CT 2 3-phase without neutral and 3 CT 3 3-phase without neutral and 2 CT A Fuse B Load 1 TV3 TV2 TV1 A B 2 TV3 TV1 A B 3 TV3 TV1 A B 18 Power meter Rev. 1.0 Chapter 4 INSTALLATION ABB 4 3-phase without neutral and 1 CT 5 Single phase connection A Fuse B Load 4 TV3 TV1 A B 5 A A B Rev. 1.0 Power meter 19 ABB Chapter 4 INSTALLATION 4.4 Configurations for first use After having cabled the instrument according to the pre-selected layout, the following operations must be carried out to start to use the analyser: 1) enter the password (see paragraph Enabling the configuration ); 2) set the language (see paragraph Language ); 3) set the CT transformation ratio (see paragraphs Primary of the CT and Secondary of the CT ); 4) set the VT transformation ratio (see paragraphs Primary of the VT and Secondary of the VT ). It is recommended to modify the password after first use as specified in the paragraph Password modification 20 Power meter Rev. 1.0 Chapter 5 OPERATION 5 OPERATING ABB 5.1 Front panel Description 1 Loop button 2 Up button 3 Down button 4 Enter button 5 Display 5a 5b K - 5c 5 5d It is possible to divide the display (5) in four main elements: minus signal (5a); measured values and configuration text (5b); magnitude indication (5c); LED energy pulse (5d). The minus signal (5a) is enabled only for variables that can present negative values (active power, reactive power, power factor, demand of active power and demand of reactive power). The measurements and texts area (5b) has four 7-segment digits with decimal points, showing numeric values or texts for configuration and data reading. The magnitude area (5c) can present the K (kilo), M (Mega) or / (percent) according to the current measured value. The LED energy pulses (5d) according to the active energy consumption. Rev. 1.0 Power meter 21 ABB Chapter 5 OPERATION 5.2 Configuration mode Accessing the configuration menu The configuration screen is accessed by following the next steps: 1) Use Loop to access the first level of the menu 2) Use Up and Down to navigate the first level of the menu 3) Use Enter to select the SET page The configuration menu allows checking and configuring all parameters of the meter. Use Up and Down to navigate the configuration menu. The following table presents all the parameters that can be configured. Parameter Ct P Ct S Ut P Ut S Wir res br byte Addr LAnG LED dcnt d Tr PASS CnFC Fir Function Primary of the CT Secondary of the CT Primary of the VT Secondary of the VT Type of connection Energy resolution Communication baud rate Communication byte format Communication address Language LED energy pulse Display control Timer display Password Critical configuration counter Firmware revision 22 Power meter Rev. 1.0 Chapter 5 OPERATION Data entry ABB Some of the pages require the entry of numerical characters (0-9) in the Configuration mode. In these cases the display will show an active field identified by a flashing number. The data entry procedure is as follows: 1) Press Up to increase the numerical characters from 0 to 9, until the required character is obtained; S E t S E t C t P C t P O x3 3 How to: Go back to a previous number If during the data entry the desired number is exceeded by mistake, it is needed to increase the displayed number until data entry starts again from 0. S E t S E t C t P C t P 3 x9 2 2) Press Down to move the cursor in order to add a second digit to the number; S E t S E t C t P C t P 2 x1 2 O Rev. 1.0 Power meter 23 ABB Chapter 5 OPERATION How to: Enable the comma Some device configurations allow entering the comma. Comma can be displayed by increasing the number with Up starts again from character 0. S E t S E t C t P C t P 2 O x10 2, after character 9 and before data entry 3) Repeat the operations described in steps 1 and 2 until the desired number is obtained 4) Press Enter to confirm the number. S E t C t P 2 O x5 S E t C t P 2 5 x1 S E t C t P 2 5 O x1 S E t C t P 2 5 O How to: Enter the magnitude Some device configurations allow entering the magnitude. Once the number has been entered as after step 4, keys Up allow enabling the magnitude K (kilo) or not. Press Enter the magnitude. S E t C t P 1 5 x1 S E t K C t P 1 5 x1 and Down to confirm S E t K C t P Power meter Rev. 1.0 Chapter 5 OPERATION ABB Enabling the configuration In order to configure the device and to change its settings, it is first necessary to enable the configuration by entering the 4-digit password. The default password is 0000; it is recommended to modify the password at the first use of the device, as explained in paragraph Password modification In order to entry the device protection password: 1) press Loop to access the first level of the menu; 2) press Up and Down to navigate the first level of the menu ; 3) press Enter to select the PASS page; 4) enter the 4-digit password as explained in Data entry Primary of the CT In order to modify the primary of the current transformer: 1) Access the Ct P page in the SET menu; 2) enter the value as explained in Data entry. S E t C t P 5 The comma can be enabled. The magnitude can be enabled Secondary of the CT In order to modify the secondary of the current transformer: 1) access the Ct S page in the SET menu; 2) press Up and Down to set the secondary of the CT, according to the table. 3) press Enter to confirm. S E t C t S 1 Parameter Description 5 5A 1 1A Rev. 1.0 Power meter 25 ABB Primary of the VT In order to modify the primary of the current transformer: 1) Access the Ut P page in the SET menu; 2) enter the value as explained in Data entry. The comma can be enabled. The magnitude can be enabled. S E t U t P Chapter 5 OPERATION Secondary of the VT In order to modify the primary of the current transformer: 1) Access the Ut S page in the SET menu; 2) enter the value as explained in Data entry. The comma can be enabled. The magnitude can be enabled. S E t U t S Type of connection In order to modify the type of connection: 1) access the Wir page in the SET menu; 2) press Up and Down to set the type of connection, according to the table. 3) press Enter to confirm. S E t U U r 3 n 3 t Parameter Description 3n3t Three phase system with neutral and three CTs 3 3t Three phase system without neutral and three CTs 3 2t Three phase system without neutral and two CTs 3 1t Three phase system without neutral and one CT 1n1t Single phase system 26 Power meter Rev. 1.0 Chapter 5 OPERATION Energy resolution In order to modify the resolution of energy: 1) access the res page in the SET menu; 2) press Up and Down to set the energy resolution, according to the table. 3) press Enter to confirm. ABB S E t r E S 2 K Energy range Range kwh kwh Communication baud rate In order to modify the communication baud rate: 1) access the br page in the SET menu; 2) press Up and Down to set the communication baud rate, according to the table. 3) press Enter to confirm. S E t b r K Parameter Description bps bps bps bps Rev. 1.0 Power meter 27 ABB Communication byte format In order to modify the communication byte format: 1) access the byte page in the SET menu; 2) press Up and Down to set the communication byte format, according to the table. 3) press Enter to confirm. S E t b t E 8 O 1 Chapter 5 OPERATION Parameter 8n2 8E1 8O1 8n1 Description 8 bits, without parity, two stop bits 8 bits, even parity, one stop bit 8 bits, odd parity, one stop bit 8 bits, without parity, one stop bit Communication Address In order to modify the communication address: 1) access the Addr page in the SET menu; 2) enter the value as explained in Data entry. The valid range of addresses for Modbus RTU slave is from 1 to 247 S E t A d d r 5 28 Power meter Rev. 1.0 Chapter 5 OPERATION Language In order to modify the language of the HMI: 1) access the LAnG page in the SET menu; 2) press Up and Down to set the language, according to the table. 3) press Enter to confirm. S E t L A n 6 E n ABB Parameter En Pt Description English Portuguese LED energy pulse In order to modify the LED energy pulse : 1) access the LEd page in the SET menu; 2) press Up and Down to set the LED option, according to the table. 3) press Enter to confirm. S E t L E d O F F Parameter OFF EP EQ Description Disabled Active power (blink frequency) Reactive power (blink frequency) Rev. 1.0 Power meter 29 ABB Display control The display can operate in two modes: manual and automatic. In manual mode, navigation between data reading pages is done by the user pressing Up and Down, as explained in Visualization of measured parameters. When the display mode is set to automatic, navigation among data reading pages on the meter is achieved according to the display timer. The display timer can be set as explained in Display timer. In order to modify the control of the display: 1) access the dcnt page in the SET menu; S E t d C n t O F F 2) press Up and Down to set the display control option; 3) press Enter to confirm. Chapter 5 OPERATION Parameter ON OFF Description Automatic control Manual control Display timer In order to set the timer of the display for the automatic control mode: 1) access the d tr page in the SET menu; 2) enter the value as explained in Data entry. S E t d t r Password modification In order to modify the device protection password: 1) access the PASS page in the SET menu; 2) enter the new 4-digit password as explained in Data entry. S E t P A S S O O O O 30 Power meter Rev. 1.0 Chapter 5 OPERATION Critical configuration counter The critical configuration counter counts how many times the critical parameters have been configured. Critical parameters are the ones which causes impact in the energy calculation, which are: primary of the CT; secondary of the CT; primary of the VT; secondary of the VT; type of connection; energy resolution. S E t C n F C 2 ABB This is a tool useful to control possible undesired changes done by the user, which may impact the energy calculation. In order to access the critical configuration counter: 1) access the CnFC page in the SET menu; It is a read only parameter Firmware revision In order to check the firmware version currently installed on the device: 1) access the Fir page in the SET menu; It is a read only parameter. S E t F r 1 O Configuration menu exit To exit from the configuration menu, press Loop. Rev. 1.0 Power meter 31 ABB Chapter 5 OPERATION 5.3 Data reading mode Accessing the data reading menu The data reading menu is accessed by follow
Search
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks
SAVE OUR EARTH

We need your sign to support Project to invent "SMART AND CONTROLLABLE REFLECTIVE BALLOONS" to cover the Sun and Save Our Earth.

More details...

Sign Now!

We are very appreciated for your Prompt Action!

x